CODE | NUCLIDE | ORIGINAL DATA TAKEN FROM | MODIFICATION | ADDITIONAL FILE MODIFICATIONS | ORIGINAL DATA TAKEN FROM | MODIFICATION | ADDITIONAL FILE MODIFICATIONS | ORIGINAL DATA TAKEN FROM | MODIFICATION | ADDITIONAL FILE MODIFICATIONS | COMMENTS |
1056138 | Ba138 | JENDL-4.0 | (1,451) Updated. (2,151) Updated. (3,1) Re-calculated from partial cross sections. (3,4) Re-calculated from partial cross sections. |
In JENDL-4, the data above 100 keV were replaced with the ones obtained by Brusegan et al./28/ The radiation widths of 95 meV and 47 meV were assumed for s- and p-wave resonances, respectively. The parameters for the negative resonance were re-adjusted so as to reproduce the thermal capture cross section recommended by Mughabghab./29/ |
JENDL-3.2 | (2,151) Resolved resonance parameters (3,102) Re-normalization (3,2), (3,4), (3,51-91) and angular distributions Small effects of the re-normalization of capture cross section. ( < 0.3% ) |
JENDL-3.2 data were automatically transformed to JENDL-3.3. Interpolation of spectra: 22 (unit base interpolation) (3,251) deleted, T-matrix of (4,2) deleted, and others. Resonance parameters in JENDL-3.3 were revised for JENDL-4. |